How do I configure a Cisco SG300 Switch for Shure Devices and Dante or AES67?
The following guide is designed to help you configure your Cisco SG300-series network switch for Dante and AES67 networks.
Before You Begin
Ensure that you have a Cisco SG300-series switch. This article only applies to Cisco SG300-series switches.
Decide how IP Addresses will be managed. It is fine to use DHCP (e.g., from a Crestron server), Static, or Self-Assigned addresses. If you are using Static IP Addresses, create a spreadsheet to keep track of each device's address. We have included a sample spreadsheet at the end of this document. We suggest tracking the device make, model, MAC Address(es), IP Address(es), firmware version, date purchased, and date installed. Include your switch in the list.
Update your switch to the latest firmware available from Cisco.
Configuring a Cisco SG300-series Switch for Shure Dante Devices
Under the Administration menu, select Management Interface > IPv4 Interface. Assign the switch an IP Address in your Dante subnet, set the correct Subnet Mask (Netmask), and set the gateway to 0.0.0.0 if this is an isolated network. Apply changes and reconnect to the switch if needed.
Under the Administration menu, select Discovery-Bonjour. Ensure Bonjour is enabled.
Under the Port Management menu, select Green Ethernet > Properties. Ensure Energy Detect Mode and 802.3 Energy Efficient Ethernet is disabled.
Under the Multicast menu, select Properties. Enable Bridge Multicast Filtering. For each VLAN, select IP Group Address" as the Forwarding Method.
Under the Multicast menu, select IPv4 Multicast Configuration > IGMP Snooping menu and enable Snooping.
Edit each VLAN in the IGMP Snooping Menu as follows:
Enable Snooping Status & Querier Status.
Set Query Interval to 30 seconds.
Select IGMPv2 as the Querier version.
Select Auto for Querier Source IP Address
Under the Multicast menu, select IPv4 Multicast Configuration > IGMP VLAN Settings and configure each VLAN as follows.
Under the Multicast menu, select Multicast Router Port and set all ports to None. This will cause the switch to Auto-Detect a Multicast Router Port if needed.
Under the Multicast menu, select Forward and set all ports to None. This will prevent multicast from Flooding all ports.
Under the Multicast menu, select Unregistered Multicast and set all ports connected to Shure equipment and your Dante Controller PC to Forward. Failure to do this may cause Dante Controller and Shure's tools to not discover any devices.
Under the Quality of Service, menu, select QoS Properties. Set mode to Basic.
Under the Quality of Service, menu, select QoS Basic Mode > Global Settings. Set Trust Mode to DSCP.
Under the Quality of Service, menu, select DSCP to Queue. Set Trust Mode to DSCP. Configure the table to look like the screenshot below with DSCP 56 set to Queue 4, DSCP46 set to Queue 3, DSCP34 set to Queue 2, and all other DSCP values set to Queue 1.
The switch is now configured. Save the settings and create a backup.
Verifying Your Work
Connect all of your Shure devices to the network switch, and if necessary, assign them a Static IP address.
Open Dante Controller and ensure all devices appear under the Device Info tab.
Verify that only one device is the Leader Clock on the Clock Status tab. All other devices should say Follower. If you are using AES67, we generally recommend that the same device serve as both the Dante and AES67 Leader Clock.
Open Shure Update Utility, and configure it to use your Ethernet adaptor. Verify that all devices appear in the list, and are on the latest firmware.